Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 14(4)2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38667166

RESUMEN

Heart failure (HF) is a clinical entity included in cardiovascular diseases affecting millions of people worldwide, being a leading cause of hospitalization of older adults, and therefore imposing a substantial economic burden on healthcare systems. HF is characterized by dyspnea, fatigue, and edema associated with elevated blood levels of natriuretic peptides, such as N Terminal pro-B-type Natriuretic Peptide (NT-proBNP), for which there is a high demand for point of care testing (POCT) devices. Optical fiber (OF) biosensors offer a promising solution, capable of real-time detection, quantification, and monitoring of NT-proBNP concentrations in serum, saliva, or urine. In this study, immunosensors based on plasmonic uncladded OF tips were developed using OF with different core diameters (200 and 600 µm). The tips were characterized to bulk refractive index (RI), anddetection tests were conducted with NT-proBNP concentrations varying from 0.01 to 100 ng/mL. The 200 µm sensors showed an average total variation of 3.6 ± 2.5 mRIU, an average sensitivity of 50.5 mRIU/ng·mL-1, and a limit of detection (LOD) of 0.15 ng/mL, while the 600 µm sensors had a response of 6.1 ± 4.2 mRIU, a sensitivity of 102.8 mRIU/ng·mL-1, and an LOD of 0.11 ng/mL. Control tests were performed using interferents such as uric acid, glucose, and creatinine. The results show the potential of these sensors for their use in biological fluids.


Asunto(s)
Técnicas Biosensibles , Péptido Natriurético Encefálico , Fibras Ópticas , Fragmentos de Péptidos , Péptido Natriurético Encefálico/sangre , Humanos , Fragmentos de Péptidos/sangre , Fragmentos de Péptidos/análisis , Insuficiencia Cardíaca/diagnóstico , Límite de Detección
2.
Biomed Opt Express ; 13(6): 3259-3274, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35781957

RESUMEN

Measuring cortisol levels as a stress biomarker is essential in many medical conditions associated with a high risk of metabolic syndromes such as anxiety and cardiovascular diseases, among others. One technology that has a growing interest in recent years is fiber optic biosensors that enable ultrasensitive cortisol detection. Such interest is allied with progress being achieved in basic interrogation, accuracy improvements, and novel applications. The development of improved cortisol monitoring, with a simplified manufacturing process, high reproducibility, and low cost, are challenges that these sensing mechanisms still face, and for which solutions are still needed. In this paper, a comprehensive characterization of a D-shaped fiber optic immunosensor for cortisol detection based on surface plasmon resonance (SPR) enabled by gold coating is reported. Specifically, the sensor instrumentation and fabrication processes are discussed in detail, and a simulation with its complete mathematical formalism is also presented. Moreover, experimental cortisol detection tests were performed for a detection range of 0.01 to 100 ng/mL, attaining a logarithmic sensitivity of 0.65 ± 0.02 nm/log(ng/mL) with a limit of detection (LOD) of 1.46 ng/mL. Additionally, an investigation of signal processing is also discussed, with the main issues addressed in order to highlight the best way to extract the sensing information from the spectra measured with a D-shaped sensor.

3.
Sensors (Basel) ; 22(6)2022 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-35336312

RESUMEN

Optical fiber technology has rapidly progressed over the years, providing valuable benefits for biosensing purposes such as sensor miniaturization and the possibility for remote and real-time monitoring. In particular, tilted fiber Bragg gratings (TFBGs) are extremely sensitive to refractive index variations taking place on their surface. The present work comprises a case-study on the impact of different methods of analysis applied to decode spectral variations of bare and plasmonic TFBGs during the detection of N-terminal B-type natriuretic peptide (NT-proBNP), a heart failure biomarker, namely by following the most sensitive mode, peaks of the spectral envelopes, and the envelopes' crossing point and area. Tracking the lower envelope resulted in the lowest limits of detection (LOD) for bare and plasmonic TFBGs, namely, 0.75 ng/mL and 0.19 ng/mL, respectively. This work demonstrates the importance of the analysis method on the outcome results, which is crucial to attain the most reliable and sensitive method with lower LOD sensors. Furthermore, it makes the scientific community aware to take careful attention when comparing the performance of different biosensors in which different analysis methods were used.


Asunto(s)
Técnicas Biosensibles , Insuficiencia Cardíaca , Técnicas Biosensibles/métodos , Insuficiencia Cardíaca/diagnóstico , Humanos , Límite de Detección , Fibras Ópticas , Refractometría
4.
Adv Mater ; 34(8): e2101326, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34288155

RESUMEN

A pressing need to develop low-cost, environmentally friendly, and sensitive sensors has arisen with the advent of the always-connected paradigm of the internet-of-things (IoT). In particular, mechanical sensors have been widely studied in recent years for applications ranging from health monitoring, through mechanical biosignals, to structure integrity analysis. On the other hand, innovative ways to implement mechanical actuation have also been the focus of intense research in an attempt to close the circle of human-machine interaction, and move toward applications in flexible electronics. Due to its potential scalability, disposability, and outstanding properties, graphene has been thoroughly studied in the field of mechanical transduction. The applications of graphene in mechanical transduction are reviewed here. An overview of sensor and actuator applications is provided, covering different transduction mechanisms such as piezoresistivity, capacitive sensing, optically interrogated displacement, piezoelectricity, triboelectricity, electrostatic actuation, chemomechanical and thermomechanical actuation, as well as thermoacoustic emission. A critical review of the main approaches is presented within the scope of a wider discussion on the future of this so-called wonder material in the field of mechanical transduction.

5.
Biosensors (Basel) ; 11(9)2021 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-34562895

RESUMEN

The evolution of optical fiber technology has revolutionized a variety of fields, from optical transmission to environmental monitoring and biomedicine, given their unique properties and versatility. For biosensing purposes, the light guided in the fiber core is exposed to the surrounding media where the analytes of interest are detected by different techniques, according to the optical fiber configuration and biofunctionalization strategy employed. These configurations differ in manufacturing complexity, cost and overall performance. The biofunctionalization strategies can be carried out directly on bare fibers or on coated fibers. The former relies on interactions between the evanescent wave (EW) of the fiber and the analyte of interest, whereas the latter can comprise plasmonic methods such as surface plasmon resonance (SPR) and localized SPR (LSPR), both originating from the interaction between light and metal surface electrons. This review presents the basics of optical fiber immunosensors for a broad audience as well as the more recent research trends on the topic. Several optical fiber configurations used for biosensing applications are highlighted, namely uncladded, U-shape, D-shape, tapered, end-face reflected, fiber gratings and special optical fibers, alongside practical application examples. Furthermore, EW, SPR, LSPR and biofunctionalization strategies, as well as the most recent advances and applications of immunosensors, are also covered. Finally, the main challenges and an outlook over the future direction of the field is presented.


Asunto(s)
Técnicas Biosensibles , Inmunoensayo , Fibras Ópticas , Metales , Resonancia por Plasmón de Superficie
6.
Nanomaterials (Basel) ; 11(8)2021 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-34443722

RESUMEN

Carbon-based electrodes have demonstrated great promise as electrochemical transducers in the development of biosensors. More recently, laser-induced graphene (LIG), a graphene derivative, appears as a great candidate due to its superior electron transfer characteristics, high surface area and simplicity in its synthesis. The continuous interest in the development of cost-effective, more stable and reliable biosensors for glucose detection make them the most studied and explored within the academic and industry community. In this work, the electrochemistry of glucose oxidase (GOx) adsorbed on LIG electrodes is studied in detail. In addition to the well-known electroactivity of free flavin adenine dinucleotide (FAD), the cofactor of GOx, at the expected half-wave potential of -0.490 V vs. Ag/AgCl (1 M KCl), a new well-defined redox pair at 0.155 V is observed and shown to be related to LIG/GOx interaction. A systematic study was undertaken in order to understand the origin of this activity, including scan rate and pH dependence, along with glucose detection tests. Two protons and two electrons are involved in this reaction, which is shown to be sensitive to the concentration of glucose, restraining its origin to the electron transfer from FAD in the active site of GOx to the electrode via direct or mediated by quinone derivatives acting as mediators.

7.
ACS Appl Mater Interfaces ; 13(8): 10210-10221, 2021 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-33619955

RESUMEN

The ability to synthesize laser-induced graphene (LIG) on cellulosic materials such as paper opens the door to a wide range of potential applications, from consumer electronics to biomonitoring. In this work, strain and bending sensors fabricated by irradiation of regular filter paper with a CO2 laser are presented. A systematic study of the influence of the different process parameters on the conversion of cellulose fibers into LIG is undertaken, by analyzing the resulting morphology, structure, conductivity, and surface chemistry. The obtained material is characterized by porous electrically conductive weblike structures with sheet resistances reaching as low as 32 Ω sq-1. The functionality of both strain (gauge factor of ≈42) and bending sensors is demonstrated for different sensing configurations, emphasizing the versatility and potential of this material for low-cost, sustainable, and environmentally friendly mechanical sensing.

8.
Biotechnol Rep (Amst) ; 29: e00587, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33489788

RESUMEN

This paper presents the development and feasibility tests of a cortisol immunosensor. The sensor is based on surface plasmon resonance (SPR) using an unclad plastic optical fiber (POF) in which the SPR is used as sensitivity enhancer, promoted by a gold/palladium (AuPd) alloy coating. The AuPd coated fibers were functionalized with an anti-cortisol antibody and passivated with bovine serum albumin (BSA) to be tested in the presence of cortisol as target analyte. The antibody-antigen binding reaction caused a variation of the refractive index on the surface of the AuPd coating, which leads to a shift of the SPR signature wavelength. The sensor was tested for different cortisol concentrations, ranging from 0.005 to 10 ng/mL. The reported biosensor presented a total wavelength shift of 15 nm for the testing range, putting in evidence a high sensitivity. Control tests for selectivity assessment were also performed. Concentrations as high as 10 ng/mL of cortisol, in a sensor functionalized with anti-hCG antibodies, only resulted in 1 nm variation of the resonance wavelength, 15 times lower than the one functionalized with the anti-cortisol antibodies, which indicates a high selectivity for the proposed approach. For this sensing approach the limit of detection (LOD) was determined to be 1 pg/mL. The proposed SPR based POF sensor has a low-cost interrogation method, high sensitivity and low LOD, straightforward signal processing and find important applications in different biological fields.

9.
ACS Appl Mater Interfaces ; 11(8): 8470-8482, 2019 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-30694644

RESUMEN

Hybrid diamond-graphite nanoplatelet (DGNP) thin films are produced and applied to label-free impedimetric biosensors for the first time, using avidin detection as a proof of concept. The DGNPs are synthesized by microwave plasma chemical vapor deposition through H2/CH4/N2 gas mixtures in a reproducible and rapid single-step process. The material building unit consists of an inner two-dimensional-like nanodiamond with preferential vertical alignment covered by and covalently bound to nanocrystalline graphite grains, exhibiting {111}diamond||{0002}graphite epitaxy. The DGNP films' morphostructural aspects are of interest for electrochemical transduction, in general, and for Faradaic impedimetric biosensors, in particular, combining enhanced surface area for biorecognition element loading and facile Faradaic charge transfer. Charge transfer rate constants in phosphate buffer saline/[Fe(CN)6]4- solution are shown to increase up to 5.6 × 10-3 cm s-1 upon N2 addition to DGNP synthesis. For the impedimetric detection of avidin, biotin molecules are covalently bound as avidin specific recognition elements on (3-aminopropyl)triethoxysilane-functionalized DGNP surfaces. Avidin quantification is attained within the 10-1000 µg mL-1 range following a logarithmic dependency. The limits of detection and of quantitation are 1.3 and 6.4 µg mL-1 (19 and 93 nM), respectively, and 2.3 and 13.8 µg mL-1 (33 and 200 nM) when considering the nonspecific response of the sensors.


Asunto(s)
Avidina/análisis , Técnicas Biosensibles/métodos , Diamante/química , Grafito/química , Nanoestructuras/química , Técnicas Electroquímicas , Ferricianuros/química , Gases/química , Límite de Detección , Propilaminas/química , Silanos/química
10.
Biosens Bioelectron ; 124-125: 167-175, 2019 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-30388558

RESUMEN

Graphene has emerged as a novel material with enhanced electrical and structural properties that can be used for a multitude of applications from super-capacitors to biosensors. In this context, an ultra-sensitive biosensor was developed using a low-cost, simple and mask-free method based on laser-induced graphene technique for electrodes patterning. The graphene was produced on a polyimide substrate, showing a porous multi-layer structure with a resistivity of 102.4 ±â€¯7.3 Ω/square. The biosensor was designed as a 3-electrode system. Auxiliary and working electrodes were made of graphene by laser patterning and the reference electrode was handmade by casting a silver ink. A molecularly-imprinted polymer (MIP) was produced at the working electrode by direct electropolymerization of eriochrome black T (EBT). As proof-of-concept, the MIP film was tailored for chloramphenicol (CAP), a common contaminant in aquaculture. The resulting device was evaluated by cyclic voltammetry and electrochemical impedance spectroscopy readings against a redox standard probe. The limit of detection (LOD) was 0.62 nM and the linear response ranged from 1 nM to 10 mM. These analytical features were better than those produced by assembling the same biorecognition element on commercial graphene- and carbon-based screen-printed electrodes. Overall, the simplicity and quickness of the laser-induced graphene technique, along with the better analytical features obtained with the graphene-based electrodes, shows the potential to become a commercial approach for on-site sensing.


Asunto(s)
Técnicas Biosensibles , Cloranfenicol/aislamiento & purificación , Grafito/química , Impresión Molecular , Espectroscopía Dieléctrica , Técnicas Electroquímicas , Rayos Láser , Polímeros/química
11.
Nanoscale Adv ; 1(8): 3252-3268, 2019 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-36133624

RESUMEN

A scalable laser scribing approach to produce zinc oxide (ZnO) decorated laser-induced graphene (LIG) in a unique laser-processing step was developed by irradiating a polyimide sheet covered with a Zn/ZnO precursor with a CO2 laser (10.6 µm) under ambient conditions. The laser scribing parameters revealed a strong impact on the surface morphology of the formed LIG, on ZnO microparticles' formation and distribution, as well as on the physical properties of the fashioned composites. The ZnO microparticles were seen to be randomly distributed along the LIG surface, with the amount and dimensions depending on the used laser processing conditions. Besides the synthesis conditions, the use of different precursors also resulted in distinct ZnO growth's yields and morphologies. Raman spectroscopy revealed the existence of both wurtzite-ZnO and sp2 carbon in the majority of the produced samples. Broad emission bands in the visible range and the typical ZnO near band edge (NBE) emission were detected by photoluminescence studies. The spectral shape of the luminescence signal was seen to be extremely sensitive to the employed processing parameters and precursors, highlighting their influence on the composites' optical defect distribution. The sample produced from the ZnO-based precursor evidenced the highest luminescence signal, with a dominant NBE recombination. Electrochemical measurements pointed to the existence of charge transfer processes between LIG and the ZnO particles.

12.
Sci Rep ; 5: 10783, 2015 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-26027718

RESUMEN

ZnO microrods were grown by laser assisted flow deposition technique in order to study their luminescence behaviour in the near band edge spectral region. Transmission electron microscopy analysis put in evidence the high crystallinity degree and microrod's compositional homogeneity. Photoluminescence revealed a dominant 3.31 eV emission. The correlation between this emission and the presence of surface states was investigated by performing plasma treatments with hydrogen and nitrogen. The significant modifications in photoluminescence spectra after the plasma treatments suggest a connexion between the 3.31 eV luminescence and the surface related electronic levels.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...